3.2 Burner and nozzle characteristics table
Burner
Rated
heating
capacity
(kW)
LPG G30/G31 28/37 mbar
(drawing ref. X238)
Nozzle
diameter
1/100 mm
By-pass
Mm
1/100
Reduced
flowrate
(W)
Flowrate
g/h G30
Flowrate
g/h G31
Auxiliary 1.05 50 30 360 76 75
Semi rapid 1.8 65 33 450 131 129
Rapid 3.0 85 45 750 218 215
Fish Burner 1.9 68 45 800 138 136
Ultra rapid 3.9 100 68 1600 262 257
UR2 Inner ring 1.0 46 30 350 73 71
UR2 Outer ring 3.5 68+68 68 1600 284 250
Burner
Rated
heating
capacity
(kW)
NATURAL GAS – G20 20 mbar
Nozzle diameter
1/100 mm
Drawing
Ref.
Reduced flowrate
(W)
Auxiliary 1.05 72 (X) 360
Semi rapid 1.8 97 (Z) 450
Rapid 3.0 115 (Y) 750
Fish Burner 1.9 94 (X) 800
Ultra rapid 3.9 126 (K) 1600
UR2 Inner ring 1.0 70 (X) 350
UR2 Outer ring 3.5 102 +102 (Z) 1600
3.3 Hob burner layout
BURNERS
1 Auxiliary
2 Semi rapid
3 Rapid
4 Ultra rapid
5 Fish
6 UR2 Inner ring
7 UR2 Outer ring
51