The power supply lead supplied is of
H07RN-F type, gauge 3 x 4 mm
2
.
For operation at 380-415V2N
or 380-
415V3N
, the power supply cable has to be
replaced with one of H07RN-F type. The
gauge of the wires in the new cable must be
at least 2.5-1.5 mm
2
(4 x 2.5 mm
2
-5 x
1.5 mm
2
), bearing in mind that the earth wire
(yellow-green) must be at least 20 mm
longer at the end for connection to the oven.
In case of connection to the electrical mains by means of socket and pin,
the connection must be completed with a three-pin plug of suitable rating
(25A), or, for operation at 380-415V2N / 380-415V3N, a five-pin plug
(16A). The power supply plug and wall socket must be of the same type
(in compliance with CEI standards). Check that the power supply line is
properly earthed. The use of reductions, adapters or junctions is not
recommended.
If a permanent connection to the electrical mains is used, the appliance's
power supply line must be fitted with an omnipolar breaking device with
contact breaking gap of at least 3 mm, located in an easily accessible
position close to the appliance itself.
WARNING: if the mains voltage drops below 190 VAC there might be
an impairment of the oven's performance; this is not due to the
appliance itself.