Instructions for the installer
If connecting by plug and socket, make sure to use a 25 Amp. three-core
plug or a 16 Amp. five-core plug in case of operation at 380-415V2N or
380-415V3N. Make sure that plug and wall socket are of the same type
and are in conformity with regulations in force. Also check that the power
supply line is provided with adequate earthing. Avoid using adapters or
shunters.
In case of permanent connection, ensure that power cable is equipped
with an easily accessible omnipolar switch fitted in proximity to the
apparatus and with a gap between contacts equal to or greater than
3 mm.
2.1.1 Safety thermostat
The oven is fitted with a safety device which trips in case of serious
malfunction. To reset, contact the nearest servicing centre.
The manufacturer declines all responsibility for damage to persons
or things caused by non-observance of the above prescriptions or by
interference with any part of the oven.
2.2 Levelling
Adjust the four feet so as to set the oven on a perfectly level plane. For
this purpose, loosen the lock nut and unscrew the foot. The range of
adjustment of the screw is 10 mm.
2.3 Steam exhaust pipe
An exhaust pipe is fitted on the back of the
oven to allow the discharge of steam
during cooking. Make sure that it's no
way obstructed and take care do not
crush it.
18