Smeg C6GGXU Range User Manual


 
Instructions for the Installer
10
4. WALL ATTACHMENT AND THE ANTI-TIP DEVICE
WARNING
- All ranges can tip.
- Bodily injury can result
- Install the anti-tip device packed with the range
- See installation instructions
FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN LOSS OF
LIFE OR SERIOUS BURNS TO CHILDREN AND ADULTS.
WARNING
ELECTRICAL SHOCK HAZARD
- Use extreme caution when drilling holes into the wall or floor. There may be
concealed electrical wiring located behind the wall or under the floor.
- Identify the location of the electrical circuits that could be affected by the
installation of the anti-tip device, then turn off power to these circuits.
- Failure to follow these instructions may result in electrical shock or other
personal injury.
CAUTION: PROPERTY DAMAGE
- Contact a qualified installer or contractor to determine the proper method for drilling holes through the
wall or floor material (such as ceramic tile, hardwood, etc.)
- Failutre to follow these instructions may result in damage to wall or floor coverings.
4.1 Instructions for wall mounting
The anti tip brackets are to be attached to the rear wall as shown. The height of the bracket location from
the floor is determined after the range legs have been adjusted to the installation height as shown in the
installation instructions and the range has been leveled.
1 Level the range
using the
adjustable
leveling legs.
2 From the floor,
measure the
height of the
notch found on
the bracket. This
notch
corresponds to
the centerline of
the holes for the
screws that will
fasten the brackets to the wall.