Smeg CE6IMX Range User Manual


 
Instructions for the installer
56
For operation on 380-415V 3N~: use an H05V2V2-F type five-core
cable (5 x 4 mm
2
).
For operation on 380-415V 2N~: use an H05V2V2-F type four-core
cable (4 x 6 mm
2
).
The earth wire (yellow-green) must be at least 20 mm longer than
the other wires at the end for connection to the appliance.
WARNING: The values indicated above refer to the cross-section of the internal conductor.
THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR DAMAGE TO PERSONS OR THINGS
CAUSED BY NON-OBSERVANCE OF THE ABOVE PRESCRIPTIONS.
15.2 Positioning and levelling the appliance (depending on model)
After making the electrical connections, level the appliance on the ground by means of its four adjustable
feet. For good cooking results, the appliance must be properly levelled. Depending on the model you
have purchased, the foot height adjustment range may vary from 70 to 95 mm and from 110 to 160 mm.
These heights refer to the distance between the highest point of the foot (fixed part) and the lowest point
(movable part which rests on the floor).