Instructions for the installer
2.2.1 Ovens with top controls
In the ovens with top controls the power cable is not supplied. Use a
H05RR-F or H05RN-F rubber-sheathed cable making sure that it does
not come into contact with any external metal parts of the oven when
routing. Remove rear cover by loosening relevant screws to gain access
to the terminal strip. If necessary change jumper configuration as shown
in the figure and then connect wires making sure that the earth wire is at
least 20 mm longer than the others. Secure power cable to oven by
means of the appropriate fitting.
.
For operation on 230V
: use an H05RR-F
/ H05RN-F type three-core cable (3 x 2.5
mm
2
).
For operation on 400V2N
: use an
H05RR-F / H05RN-F type four-core cable
(4 x 2.5 mm
2
).
For operation on 400V3N
: use an
H05RRF / H05RN-F type five-core cable
(5 x 1.5 mm
2
).
The cable end to be connected to the
appliance must be provided with an ground
wire (yellow-green) at least 20 mm longer.
The manufacturer declines all responsibility for damage to persons
or things caused by non-observance of the above prescriptions or by
interference with any part of the appliance.
7