Smeg NCT685BSG Cooktop User Manual


 
Instructions for the installer
13
Burner
Rated
heating
capacity
Town gas G110 – 0.8 kPa
Nozzle diameter
1/100 mm
Reduced flowrate
(W)
Auxiliary 1.05 132 380
Semirapid 1.65 165 380
Rapid 2.55 210 600
Rapid large 3.1 240 800
Fish pan 1.8 177 750
Ultra rapid 3.3 250 900
Internal 0.8 115 380
Double
crown
External 3.3 250 900
Regulation of primary air
Referred to distance “X” in mm.
Burner
G20
2.0 kPa
G30/G31
2.8 kPa
G110
0.8 kPa
Auxiliary (1) 1.5 1.0 0.5
Semirapid (2) 1.5 1.5 0.5
Rapid (3) 1.0 1.5 1.0
Rapid large (4) 1.5 2.5 1.0
Fish pan (7) 2.5 2.0 1.0
Ultra rapid (5) 1.5 2.5 1.0
Internal 1.5 1.5 0.5
Double
crown (6)
External 1.5 4.0 1.0