Instructions for the installer
13.2 Positioning the oven
The appliance is designed for building-in to cabinets made from any heat-
resistant material. Comply with the dimensions shown in figures 1, 2, and
3. When installing under worktops, comply with the dimensions shown in
figure 1-3. When installing under worktops incorporating combined hobs,
a gap of at least 110 mm must be left from any side wall, as shown in
figure 1.
When installing in tall units, comply with the dimensions shown in figure 1-
2, bearing in mind that the top/rear of the unit must have an opening 80-90
mm deep. Screw the 4 screws A into the inside of the frame (fig. 1). For
installation under counter-top hobs, make sure that the rear/bottom of the
unit has an opening similar to that shown in figure 1 (ref. B). See the
instructions supplied with the hob for the relative positioning and fixing
procedures.
Never use the door for leverage when inserting
the oven in the cabinet. Never apply excessive
pressure to the open door.