Smeg T18G8X2UG Cooktop User Manual


 
48
Instructions for the Installer
10.2 Burner and Nozzle Data Tables
Burner
RATED
HEAT
CAPACITY
(
KW)
LPG GAS – G30/G31 28/37 mbar
Nozzle
diameter
1/100 mm
By-pass
mm
1/100
Reduced
heat
capacity
(W)
Net
g/h G30
Net
g/h G31
Auxiliary (1) 1.05 50 30 350 763 750
Semi-rapid (2) 1.75 65 33 450 127 125
Rapid (3) 2.3 75 45 800 167 164
Ultra-rapid (4) 3.5 94 65 1500 254 250
Ultra-rapid (5) 3.9 100 65 1500 284 279
Fish (6) 1.9 65 40 900 138 136
Burner
RATED
HEAT
CAPACITY
(
KW)
NATURAL GAS – G20 20 mbar
Nozzle diameter
1/100 mm
Reduced heat capacity
(W)
Auxiliary (1) 1.05 72 350
Semi-rapid (2) 1.75 97 450
Rapid (3) 2.5 108 800
Ultra-rapid (4) 3.5 133 1500
Ultra-rapid (5) 3.9 135 1500
Fish (6) 1.9 94 900
To identify the burners on your hob, refer to the drawings in point "4.