SEZ SERIES COUNTERTOP STEAMERS TROUBLESHOOTING
OPERATOR’S MANUAL 1181587 PAGE 21
TROUBLESHOOTING
Excessive Steam Coming from Pressure Relief Vent
Excessive steam coming from pressure relief vent.
DISCONNECT POWER AT CIRCUIT BREAKER.
Check pressure switch for proper operation (see Figure 17 on page 34).
Pressure switch OK?
No
Replace pressure switch.
Reconnect power.
Excessive steam?
Check contactor and
replace as necessary
(see Figure 11 on page
28).
Yes No
Yes
Remove control panel, but leave plug connected.
Check controller (see Figure 15 on page 32).
Replace as necessary.
Wait 20 minutes.
Reinstall control panel,
reconnect power.