Southbend SEZ-5 Electric Steamer User Manual


 
SEZ SERIES COUNTERTOP STEAMERS TROUBLESHOOTING
OPERATORS MANUAL 1181587 PAGE 29
TROUBLESHOOTING
Figure 12
Timer and Buzzer Check
Buzze
r
Time
r
1. DISCONNECT POWER AT CIRCUIT BREAKER.
2. Remove control panel.
3. Set timer for one minute and allow to time out. If timer does not run, then replace.
4. Remove buzzer lead wires from timer and terminal block position 6.
5. Place test leads between positions 1 and 3 on the timer.
6. Check for continuity. If no continuity, replace timer.
7. Place test leads in terminals of buzzer lead wires.
8. Check that resistance is approximately 3.4 Kohms. Otherwise, replace buzzer.