TROUBLESHOOTING
Figure 13
Door Switch Continuity Check
215436
9
8
7
5
312
Door Switch
Controlle
r
Terminal Block
1. DISCONNECT POWER AT CIRCUIT BREAKER.
2. Remove control panel.
3. Depress and release door switch actuator rod to make sure door switch is properly actuated.
4. Remove door switch lead wires from terminal block position 1 and terminal 8 of the controller.
5. Place test leads as shown inside the terminal connectors of the lead wires.
6. Check for continuity - (there should be NO continuity).
7. Depress door switch actuator rod and check for continuity - (there should be continuity).
8. Replace as necessary.