STRATOSTEAM COUNTERTOP STEAMER SERVICE
Figure 12
Steamer Not Heating Up Properly or Not Cooking Properly, “Power” Light is Lit
Steamer not heating properly or not cooking properly,
“Power” light is lit.
Replace door switch.
Reconnect door switch lead wires.
Door switch OK?
No Yes
Check door switch (see page 34).
DISCONNECT POWER AT CIRCUIT BREAKER
Is water level at
normal level in cavity?
No Yes
Turn off steamer and check that it drains completely. If steamer
does not drain, check drain path for obstructions. Turn steamer
back on and wait 10 minutes.
High-limit thermostats OK? No
Yes
Replace high-limit
thermostats as necessary.
DISCONNECT POWER AT CIRCUIT BREAKER Check that water-supply pressure is adequate.
Check high-limit thermostats (see page 35).
Check gas supply valve.
Replace water solenoid.
Water solenoid OK?
No Yes
Check water solenoid (see page 36).
Check for loose or broken
wires (see wiring diagram).
If wiring is OK, remove screen
from strainer and clean or
replace as necessary.
Reassemble, reconnect, and
recheck the steamer. If water
still does not enter the
steamer, examine the water
solenoid and inline Y strainer
for obstructions or deposits.
Clean or replace as
necessary.
Check gas supply valve.
Check gas pressure.
OWNER’S MANUAL 1185290 PAGE 25 OF 50