PREPARATION FOR USE
Do not operate the power unit until you have read the
engine operating and maintenance instructions manual
furnished with the unit.
1. ENGINE CRANKCASE OIL LEVEL
Always check the oil level before starting the engine. Make
sure the oil level is at the FULL MARK on the dipstick. Do
not overll. Use detergent oil classied "For Service SE,
SF, SG" as specied in the engine operating and mainte-
nance manual. See engine manual for oil viscosity grade.
2. SPARK PLUG
On power units equipped with Briggs & Stratton Engines,
ONLY Champion RC12YC or equivalent can be used.
Incorrect type spark plugs can produce radio frequency
interference that will corrupt and damage the controller.
Failure to use the correct spark plug could result in a war-
ranty that will not be considered.
3. ENGINE FUEL LEVEL
Check the fuel level. If low, ll with un-leaded gasoline with
a minimum of 85 octane.
4. HYDRAULIC FLUID
Check the dip stick in the hydraulic uid reservoir for the
proper uid level. Use uids meeting the following speci-
cations.
Viscosity (Fluid Thickness)
U.S. METRIC
50°F 450 SSU Maximum 10°C 95 C.S.
100°F 130-200 SSU 38°C 27-42 C.S.
140°F 85 SSU Minimum 60°C 16.5 C.S. Min
Pour Point -10°F/-23°C Minimum (for cold startup)
Viscosity Index (ASTM D-2220) 140 Minimum
Demulsibility (ASTM D-1401) 30 Minutes Maximum
Flash Point (ASTM D-92) 340°F/171°C Minimum
Rust Inhibition (ASTM D-665 A & B) Pass
Oxidation (ASTM D-943) 1000 Hours Minimum
Pump Wear Test (ASTM D-2882) 60 mg Maximum
The following uids work well over a wide temperature
range, allow moisture to settle out and resist biological
growth that may occur in cool operating hydraulic circuits.
These uids are recommended by Stanley. Other uids
that meet or exceed the specications of these uids may
also be used.
Chevron AW-MV-32
Exxon "Univis" J-26
Mobil D.T.E. 13
Gulf "Harmony" AW-HVI-150-32
Shell "Tellus" T-32
Texaco "Rando" HD-AZ
Union "Unax" AW-WR-32
Terresolve EnviroLogic 132
5. HYDRAULIC CONNECTIONS
The recommended hose length is 25 ft/8 m with a 1/2
inch/12.7 mm inside diameter. The hoses must have a
working pressure rating of at least 2500 psi/175 bar. Each
hose end must have male thread ends compatible with
H.T.M.A. (HYDRAULIC TOOL MANUFACTURERS AS-
SOCIATION) quick disconnect ttings (NPT type threads).
(See Figure 2.)
Figure 1. Control Panel
Facing the control panel, the bottom male quick disconnect
tting is the PRESSURE FLUID OUT tting. The top female
quick disconnect tting is the RETURN FLUID IN tting.