Stanley Black & Decker GT18B01 Food Saver User Manual


 
GT18B01-B02 User Manual ◄ 11
OPERATION
QUICK DISCONNECT COUPLERS
H.T.M.A. approved quick disconnect couplings are installed
to hydraulic hoses so that the direction of oil ow is always
from the male to the female quick disconnect as shown in
gure 2. Quick disconnect couplings and hose ttings are
selected so that additional ttings such as reducer or adapt-
er ttings are not required.
If adapter ttings are used, they must be approved steel
hydraulic ttings meeting a minimum operating pressure
rating of 2500 psi/172 bar. Do not use galvanized pipe t-
tings or black pipe ttings.
Use thread tape or pipe joint compound when installing
quick disconnect couplings to hose or tool ttings. Follow
the instructions furnished with the selected thread sealant.
DO NOT OVERTIGHTEN THE FITTINGS.
6. BATTERY
NOTICE
Do not charge the battery with a standard automotive
battery charger. This type of charger produces a
charging amperage higher than 2 amps. Charging
the battery at higher than 2 amps will damage the
battery.
NOTICE
If the engine runs out of gas or dies during operation
and the ignition switch is left in the ON or RUN
position, this could drain the battery. Make sure the
ignition switch is returned to the OFF position.
H.T.M.A. 1/2 INCH MALE
QUICK DISCONNECT
COUPLER
CONTROL PANEL
RETURN
PRESSURE
H.T.M.A. 1/2 INCH FE-
MALE QUICK DISCON-
NECT COUPLER
1/2 INCH I.D. HOSE, 25 FT
LONG WITH 2500 PSI/
172 BAR RATING AND
4 TO 1 SAFETY FACTOR
1/2 INCH MALE PIPE HOSE END
1/2 INCH MALE PIPE HOSE END
ADAPTER, 3/8 INCH MALE PIPE x
-8 SAE O-RING
H.T.M.A. 1/2 INCH MALE
QUICK DISCONNECT
COUPLER
H.T.M.A. 1/2 INCH FE-
MALE QUICK DISCON-
NECT COUPLER
TOOL
PRESSURE
RETURN
RETURN
PRESSURE
Figure 2
CONTROL PANEL