18 ► GT18B01-B02 User Manual
TROUBLESHOOTONG
ENGINE WILL NOT START. FLOW SELECTOR SWITCH NOT MAKE SURE THE FLOW SELECTOR SWITCH IS IN
IN THE OFF POSITION. THE OFF POSITION WHEN STARTING.
BATTERY NOT CONNECTED. ATTACH BATTERY CABLES, CHECK WIRES.
WEAK BATTERY. TEST BATTERY, CHARGE OR REPLACE.
NO FUEL. ADD FUEL.
FUEL FILTER PLUGGED. REPLACE FUEL FILTER.
DEFECTIVE SPARK PLUGS. REMOVE PLUGS, CHECK GAP, CLEAN OR REPLACE.
FLUID BLOWING OUT OF FLUID
RESERVOIR VENT. HYDRAULIC TANK OVERFILLED. CORRECT THE FLUID LEVEL.
PUMP SUCTION LEAK. CHECK SUCTION CONNECTIONS. TIGHTEN IF
NECESSARY.
HYDRAULIC TOOL WON'T OPERATE FLOW SELECTOR SWITCH NOT CHECK THAT THE FLOW SELECTOR SWITCH
SWITCHED ON. IS SET TO 5 OR 8 GPM.
INCORRECT HOSE CONNECTION MAKE SURE THE TOOL HOSE CIRCUIT GOES
TO TOOL. FROM LEFT (PRESSURE) FITTING TO TOOL AND BACK TO
THE RIGHT FITTING (RETURN). FLUID ALWAYS FLOWS
FROM THE MALE TO FEMALE FITTINGS.
QUICK DISCONNECT FITTINGS DETACH FROM HOSE, CONNECT SET
DEFECTIVE. TOGETHER AND CHECK FOR FREE FLOW.
HYDRAULIC FLUID LEVEL LOW. CHECK FOR CORRECT FLUID LEVEL. FILL USING THE
RECOMMENDED FLUID.
PUMP COUPLING DEFECTIVE. WITH THE ENGINE NOT RUNNING.
CHECK THE COUPLING BETWEEN THE PUMP
AND ENGINE THAT IT IS ENGAGED AND IS
NOT DAMAGED. CAUTION: KEEP HANDS
CLEAR OF ROTATING OBJECTS.
RELIEF VALVE STUCK OPEN. ADJUST OR REPLACE VALVE.
SUCTION HOSE KINKED. MAKE SURE SUCTION HOSE FROM FLUID RESERVOIR TO
PUMP INLET HAS A SMOOTH CURVE.
SOLENOID NOT WORKING. CHECK SOLENOID OPERATION AND ELECTRICAL
CONNECTIONS
.
TOOL IS DEFECTIVE. REFER TO TOOL MANUAL.
PROBLEM CAUSE REMEDY