Stoelting E112 Freezer User Manual


 
7
E. After five minutes, place a bucket under the spigot
and open spigot to drain sanitizing solution. Place
the switch in the OFF (middle) position. Loosen
freezer door and allow the freezing cylinder to drain
completely. Re-tighten door.
F. If using a shake mix, install the mix inlet regulator
into hopper (Refer to Figure 3-3). If using a slush
mix, the mix inlet regulator is not required.
3.4 FREEZE DOWN AND OPERATION
This section covers the recommended operating proce-
dures for the safe operation of the freezer.
A. Sanitize just prior to use.
B. Place the switch in the OFF (middle) position.
NOTE
Make sure the mix inlet regulator is in place before
adding shake mixes. This is not necessary for slush
mixes.
C. Pour approximately 1/2 gallon of fully thawed mix
into the hopper. Open spigot and drain a small
amount of mix to remove any remaining sanitizer.
D. Fill hopper with pre-chilled (40°F or 4°C) mix.
NOTE
Do not overfill the hopper. Mix level must not be
higher than the air inlet tube on the mix inlet regula-
tor.
E. Place the switch in the ON position.
NOTE
After the drive motor starts, there is a 3 second de-
lay before the compressor starts.
F. After 8 to 12 minutes the product will be at
consistency and will be ready to serve. Freeze
down time may vary depending on mix type and
ambient temperatures.
G. For normal dispensing, pull the spigot handle down
to open the spigot.
H. The freezer is designed to dispense the product at
a reasonable draw rate. If the freezer is overdrawn,
the result is a soft product or a product that will not
dispense at all. If this should occur, allow the
freezer to run for approximately 30 seconds before
dispensing additional product.
I. Do not operate the freezer when the ADD MIX light
and MIX OUT lights are on. Refill the hopper
immediately.
3.5 MIX INFORMATION
Mix can vary considerably from one manufacturer to an-
other. Differences in the amount of butterfat content and
quantity and quality of other ingredients have a direct
bearing on the finished frozen product. A change in freezer
performance that cannot be explained by a technical
problem may be related to the mix.
Proper product serving temperature varies from one
manufacturer’s mix to another. Shake and stackable slush
mixes provide satisfactory product from 24° to 28°F (-4° to
-2°C).
When checking the temperature, stir the thermometer in
the frozen product to obtain an accurate reading.
Old mix or mix that has been stored at elevated tempera-
tures will produce poor-quality product with a bad taste and
unacceptable appearance. To retard bacteria growth in
dairy based mixes, the best storage temperature range is
between 36° to 40°F (2.2° to 4.4°C).
Some shake mixes tend to foam more than others. If foam
appears in the hopper, skim off with a sanitized utensil and
discard. Periodically, stir the mix in the hopper with a
sanitized utensil to help prevent excess foam.
3.6 REMOVING MIX FROM FREEZER
To remove the mix from the freezer, refer to the following
steps:
A. If removing shake mix, pull the mix inlet regulator
straight up and remove it from the hopper.
B. Place the switch in the CLEAN position to rotate
the auger. Allow the mix to agitate in freezing
cylinder until the mix has become liquid, about 5
minutes.
C. Drain the liquid mix by opening the spigot. A
container should be placed under the spigot to
collect the liquid mix.
D. Place the switch in the OFF (middle) position.
3.7 CLEANING THE FREEZER
NOTE
The frequency of cleaning the freezer and freezer
parts must comply with local health regulations.
After the mix has been removed from the freezer, the freezer
must be cleaned. To clean the freezer, refer to the following
steps:
Figure 3-2 Mix Inlet Regulator