INSTALLATION INSTRUCTIONS - GAS
CONNECT TO THE ELECTRICITY SUP-
PLY
(mains ignition models only)
Warning:Thisappliancemustbeearthed.
Theexiblemainsleadissuppliedcon-
nected to a BS 1363 fused plug, the plug
isttedwiththecorrectfuse.
Replace only with a fuse of the same rat-
ing and type.
The wires in the mains lead are coloured
inaccordancewiththefollowingcode:
Green and yellow = Earth,
Blue = Neutral,
Brown = Live.
As the colours of the wires in the mains
lead for the appliance may not corre-
spond with the coloured markings identi-
fying the terminals in your plug, proceed
asfollows:
1. The wire which is coloured green
and yellow must be connected to the
terminal marked E (Earth) or coloured
Green.
2. The wire which is coloured
blue must be connected to the terminal
marked N (Neutral), or coloured Black.
3. The wire which is coloured brown must
be connected to the terminal marked L
(Live), or coloured Red.
The plug and socket must be accessible
after installation. Should the mains lead
of the appliance ever require replacing,
thismustbecarriedoutbyaqualied
electrician who will replace it with a lead
of the same size and temperature rating.
Important:-ensurethatyourouteall
mainsandelectricalcablesandexible
tubing well clear of any adjacent heat
source.
Under no circumstances should the mains
electric cable be allowed to come into
contactwiththeverticalovenuetubes
on the rear of the appliance.
PRODUCTS WITH CAST IRON LID
(WHERE FITTED)
A 55mm clearance is required from the
back of the hotplate to the rear wall, to
allow the lid to be opened fully. To ensure
thisclearanceismaintained,theinll
piece(supplied)shouldbettedusingthe
instructions below.
Fittingtheinllpiecebetweentherearof
the hob and the wall
Fixtheinllpiecetothewall-using
suitablescrewsandwallxings(not
supplied) - and ensure it is level with the
hotplate as shown.
Note:The55mmclearancedimension
should not be reduced.
550mm
55mm
(Neutral),
3.
be connected to the terminal marked
(Live),
The plug and socket must be accessible
after installation. Should the mains lead of
the appliance ever require replacing, we
recommend that this is carried out by a
qualied electrician who will replace it with
a lead of the same size and temperature
rating.
must be connected
marked N (N eu
Black.
3. The wire which
must be connected
marked L (Live),
The plug and
acce ssible after insta
Should the main
appliance ever requ
E (Earth)
Green/Yellow
N (Neutral)
Blue
L (Live)
Brown