ELECTRICAL REQUIREMENTS
A 220-240 V AC, 50/60 Hz, 10 amp circuit
breaker and electrical supply are required. A
separate circuit, servicing only this appliance,
is required.
The power supply cord has a grounding plug,
which must be plugged into a mating ground -
ing-type wall recep tacle. Follow all National
Electrical codes and local codes and ordinances
when installing the receptacle. For location of
the electrical supply, refer to the Installation
Specifications illustration on page 3.
IMPORTANT NOTE:
For Models ICB424 and
ICB424FS, the outlet must be flush with the
back wall.
IMPORTANT NOTE:
A ground fault circuit
interrupter (GFCI) is not recommended and
may cause interruption of operation.
HOME ALARM SYSTEM
If a home alarm system is to be used, refer to
Home Alarm Connections on page 8. In addition
to operating power, the installer may also be
required to supply a home automation system
lead to the unit. This is for a low-voltage, low-
current signal similar to door and window
sensor signals. Common, normally open and
normally closed contact configurations are
provided.
Three 6 mm female spade connectors are
located in the compressor compartment and
are accessible behind the kickplate on Models
ICB424 and ICB424FS. A minimum of 914 mm
of lead wire should be provided for each
contact, exiting the back wall near the
electrical outlet.
MODELS ICB424 AND ICB424FS INSTALLATION
UNPACKING AND MOVING
Uncrate the unit, remove its wood base and
discard the shipping bolts that hold the wood
base to the bottom of the unit. Remove all
packing materials and tape.
IMPORTANT NOTE:
Do not discard the kick-
plate, anti-tip bracket and hardware. These
items will be needed for the installation.
All roller-assembly wine shelves should be
removed to reduce weight and prevent them
from rolling. To remove, pull the shelf out to
its full extension, gently and evenly lift up on
both sides of the front of the shelf and remove.
Reverse the procedure to reinstall the shelf.
Use an appliance dolly to move the Wine
Storage unit. Position the dolly at the back
of the unit to prevent damage to finished
surfaces.
Do not use an extension cord. Electrical
ground is required on this appliance.
Before moving the Wine Storage unit in
to position, protect any finished flooring
with appropriate materials and secure
the door closed.
MODELS
ICB424
ICB424FS