Taylor 342 Freezer User Manual


 
21
Models 340, 341, 342 Important: Operator Checklist
Winter Storage
If the place of business is to be closed during the winter
months, it is important to protect the freezer by
following certain precautions, particularly if the
building is subject to freezing conditions.
Disconnect the freezer from the main power source to
prevent possible electrical damage.
On water cooled freezers, disconnect the water
supply. Relieve pressure on the spring in the water
valve. Use a ir pressure on the outlet side to blow out
any water remaining in the condenser, and then add a
liberal amount of per manent type auto anti-freeze.
This is extremely important. Failure to follow this
procedure may cause severe and costly damage to the
refrigeration system.
Your local Taylor Distributor can perform this service
for you.
Wrap detachable parts of the freezer such as beater,
blades, d rive shaft, and freezer door, and place i n a
protected dry place. Rubber trim parts and gaskets
can be protected by wrapping them with
moisture-proof paper. All par ts should b e thoroughly
cleaned of dried mix or lubrication which attract mice
and other vermin.