Taylor 342 Freezer User Manual


 
22
Models 340, 341, 342Troubleshooting Guide
Section 8 Troubleshooting Guide
PROBLEM PROBABLE CAUSE REMEDY PAGE
REF.
1. No product i s being
dispensed with the draw
valve opened.
a. Improper mixing of
product.
a. Carefully follow the
directions for mixing the
product.
-- --
b. There is a mix low
condition.
b. Add mix to the mix
hopper.
9
c. The torque arm i s not
installed.
c. Install the torque arm.
d. The torque rotor is bent or
improperly installed.
d. Replace the bent rotor or
follow the assembly
procedures.
11
2. The product is too thin. a. Improper mixing of
product.
a. Carefully follow the
directions for mixing
product.
-- --
b. Scraper blades are
missing or incorrectly
installed.
b. Replace or install the
scraper blades correctly.
10
c. The consistency control
knob needs adjusting.
c. Adjust accordingly. 9
d. The torque rotor bound,
leaving the torque arm in
the “COLD” position.
Therefore, the compressor
will not run. (Far Right)
d. Free the torque rotor . -- --
3. The product is too stiff. a. The torque rotor bound,
leaving the torque arm in
the “WARM” position.
Therefore, the compressor
continually runs. (Far Left)
a. Free the torque rotor . -- --
b. The torque arm i s bent or
is missing.
b. Install o r replace the
torque arm.
13
c. The consistency control
knob needs adjusting.
c. Adjust accordingly. 9
d. Improper mixing of
product.
d. Carefully follow the
directions for mixing
product.
-- --
e. There is insufficient
product in the freezing
cylinder.
e. Keep the hopper full of
mix.
9