Thermador 98 Cooktop User Manual


 
INSTALLATION WITH OTHER COOKTOPS WHERE SPECIFIED
(SEE PART B)
Figure 8
34-1/2" - UCV36
OW
CW
28-1/2" - UCV30
1/8"
OD
CD
SB
2-1/4"
BT
43-1/2" - UCV45
The installer will need to have the cooktop installation
instructions available to complete the installation. All
cooktop dimensions should be verified through measure-
ment prior to cutting the countertop:
CCW = Cooktop Cutout Width
CCD = Cooktop Cutout Depth
COW = Cooktop Overall Width
COD = Cooktop Overall Depth
with the above dimensions confirmed, determine the
cutout size as follows:
1 . Find the cutout width, (CW):
If CCW is smaller than the UCV cutout width
then:
Installation CW
UCV30 28
-
1
/2
UCV36 34
-
1
/2
UCV45 43
-
1
/2
If CCW is larger than the UCV cutout width then:
CW = CCW
See Figure 8 for UCV cutout widths and dimension
definitions.
2 . Calculate the cutout depth, CD:
Determine the cooktop overhang (CO)
CO = (COD-CCD)/2 (Assumes front and rear
cooktop overhangs are equal) Calculate the cutout
depth, (CD):
CD = COD - CO+1
-
7
/8"
3 . Determine setback (SB) distance from
front of countertop to front of cutout. SB is
specified in the installation instructions shipped
with the cooktop.
4 . Backsplash thickness must not exceed BT
as calculated below:
BT = 24
7
/8" - SB+CO - OD - 2-1/4
(Provides
1
/8" clearance between vent and
backsplash.) A negative value for BT means
countertop is too small for the installation.
5 . Verify that the available flat countertop
has a width greater than OW and a depth
greater than OD.
OW depends on the installation:
UCV30: OW equals the greater of COW or 30".
UCV36: OW equals the greater of COW or 36".
UCV45: OW equals the greater of COW or 45".
OD is determined by: OD=COD+2
-
1
/4".
6. Cut countertop using dims: CD, CW and SB as
defined in Figure 8.
B. INSTALLATION WITH ANOTHER BRAND OF COOKTOP (Figure 8)
Page 9
* Refer to Table 3 Notes on previous page.