Thermador CGX456 Cooktop User Manual


 
CABINET CONSIDERATIONS AND COUNTERTOP CUTOUT
Dimension requirements in Figs. 1 & 2 are for
combustible surfaces. When the surface is protected
by a material listed by UL as a Floor Protector and Wall
Shield (UL Cat. DFCV) covered with not less than No.
28 MSG sheet metal, 0.015 inch stainless steel, 0.024
inch aluminum or copper, it is considered noncombustible
and some dimensions may be reduced. For a
noncombustible surface over the cooktop, the minimum
clearance is 24" rather than 30".
NOTICE: All measurements given have to be precisely
followed. If non-standard cabinets are used, care should
be taken to alter dimensions accordingly.
Plan the installation of the unit so that the power cord
receptical or junction box, gas shut-off valve and gas
pressure regulator are accessible from the front of
cabinet. If a drawer is installed directly under the
cooktop, its depth (front to back) should be no greater
than 15".
Cooktop Installation over a Thermador oven.
The cooktop can be installed over a single Thermador
®
electric oven: models CT130, S301 or SC301. The
cooktop should be located on the same center line as
the under-the-counter single oven. See specific oven
Installation Instructions for the location of the junction
boxes. This installation is an IAS approved installation.
Page 21
Fig. 1 Installed Dimensions
(from cooktop edges)
Depth from Front to Back
Cabinet 13" Max.
Hood Depth 24" Max.
To Left Side
Wall 6" Min.
18" Min.
Cooktop to Front of Countertop - 1-1/4" Min.
Dimensions are minimum clearances to Combustible Materials
For Cutout Dimensions See Fig. 2
To Right Side Wall
3" Min.
Above Counter 30" Min. to
Combustible Surface
CGX304 - 30" Min.
CGX365/CD365 - 36" Min.
CGX456/CD456 - 45" Min.
Centered Over Cooktop