Thermador GGN36 Cooktop User Manual


 
TESTED IN ACCORDANCE WITH ANSI
Z21.1, STANDARD FOR HOUSEHOLD
COOKING GAS APPLIANCES, and CAN/
CGA 1.1 DOMESTIC GAS RANGES.
Check your local building codes for the
proper method of installation. In the ab-
sence of local codes this unit should be
installed in accordance with the National
Fuel Gas Code No. Z223.1 Current Issue
and National Electrical Code ANSI/NFPA
No. 70 Current Issue or the CAN - B149
Installation Codes for Gas Burning Appli-
ances and C22.1 Canadian Electrical Code
Part 1.
PROPANE GAS INSTALLATION
The cooktop is ready for use with natural gas. It
may be converted for use with propane gas
using the Burner Propane Conversion Kit, Model
NLPKIT6, Part Number 35-00-688. A qualified
service techhnican or installer can convert the
cooktop. Be sure the unit being installed is
correct for the type of gas being used. Refer to
the Rating plate on the right side underneath
the cooktop, see pages 7 to 10 for the location.
CAUTION
When connecting the unit to propane gas, make
certain the propane tank is equipped with its
own high pressure regulator. In addition the
pressure regulator supplied with the cooktop
must be on the inlet gas pipe of this unit. The
maximum gas pressure to this appliance is
not to exceed 14.0 inches water column from
the propane gas tank pressure regulator.
PROPANE INSTALLATION