A. Motor OFF button
B. ON button and motor speed
selection button 1, 2, 3, 1,....
C. Speed 1LED
D. Speed 2 LED
E. Speed 3 LED
F. Timer LED
G. Timer.
If the motor is off while the ti-
mer is pressed the motor will
run at speed 3 for 20 minutes
then stop.
If the motor is running when
the timer key is pressed the
motor will continue to run for 10
minutes. After 10 minutes the
motor will stop.
Pressing the timer or speed
button while the Timer LED is
on will disable the timed mode.
H. Light ON/OFF button.
I. Dim Light ON/OFF button.
Grease Filter Saturation LED
The speed 2 LED in Figure 1 in is
marked with an F. This LED will
flash to remind you when the grease
filter needs to be cleaned after 40
hours use. Follow the instructions
for cleaning filters in thisFollow
the instructions for cleaning filters
in this booklet. Once the grease
filters have been cleaned, reset
the display by pressing button A for
Circuit Self-test
The control allows the user to
perform a self-test to check the
correct function of the hood.
The self test is activated by
pressing the A and B keys
simultaneously for 3 seconds.
The self-test procedure order is:
1. Four LED’s switch on.
2. Four LED’s switch off.
3. Blower runs at speed 1.
4. Blower runs at speed 2.
5. Blower runs at speed 3.
6. Blower off.
7. Lights switch on.
8. Lights dim.
9. Lights turn off.
10. Beep signals end of self-test.
OPERATING
INSTRUCTIONS - HOOD
The blower should be turned on
for 10 minutes before cooking in
order to establish air currents
through the hood. This will
improve the capture and removal
of heat, smoke, moisture, grease
and cooking odors. Use the low
speeds for normal use and the
higher speeds for strong odors or
fumes.
Drafts across the range or
cooktop will reduce the effective-
ness of the hood. Such drafts
should be prevented when
possible.
CONTROL PANEL
MODEL: HNW
ELECTRONIC TOUCH CONTROLS
Fig. 1