6.
Replace with a new halogen bulb. Grasp the new bulb
with a clean, dry cloth. Press the 2 pins on the bulb
into the socket holes until the bulb is firmly seated.
7.
Screw the glass cover back on.
8.
Turn power back on at the main power supply (fuse or
breaker box).
To replace the halogen bulb on the oven sidewall:
1.
Turn off power to the oven at the main power supply
(fuse or breaker box).
2.
Remove oven racks if necessary to provide access to
the bulb housing.
3.
Optional: remove oven door to provide easier access
and visibility.
4.
Insert the tip of a narrow flat blade screwdriver
between the metal clips at about a 40° angle. The
screwdriver blade must be able to pass between the
metal clips to reach the inner catch.
5.
(A) Push the screwdriver blade inward to disengage
the catch from the slot in the light housing.
Support the glass lens cover to prevent it from falling.
6.
(B) Gently pry the lens off by moving the screwdriver
handle away from the oven wall. The lens should
detach easily. Do not attempt to force it.
7.
Pull the halogen bulb from its socket. If it is difficult to
grasp the bulb using one hand, use both forefingers to
pinch behind the rounded part of the bulb, then pull
the bulb out using both hands.
8.
Replace the halogen bulb. Grasp the new bulb with a
clean, dry cloth. Align the bulb prongs with the socket
holes and press into place.
Direct finger contact with the bulb may cause
premature bulb failure.
9.
Put the glass cover back on by inserting it into the
mounting clip and pressing the end nearest you into
the housing until it locks into place.
10.
Turn power back on at the main power supply (fuse or
breaker box).
Tools required
Narrow flat blade screw-
driver (blade tip width 1/
5" (5 mm) or less to fit in
slot).
Flashlight (to see socket
holes to plug in bulb
prongs).
èɊȯPP