11
Step 4: Installing Anti -Tip Device
30" and 36" Ranges (Figures 7A and 7B)
Thermador Service Part No. Qty Description
415078 4 Screw, Phillips, #10 x 1-1/2"
487310 1 Anti-Tip Bracket, Floor-Mounted
• The anti-tip bracket may be attached to a solid
wood cabinet having a minimum wall thickness of
3/4".
• The thickness of the wall or floor may require use
of longer screws, available at your local hardware
store.
• In all cases, at least two (2) of the bracket mount-
ing screws must be fastened to solid wood or
metal.
• Use appropriate anchors when fastening the
mounting bracket to any material other than hard-
wood or metal.
• Prepare holes at fastener locations as identified
below:
-
For walls, wall studs, or floors composed of
solid wood or metal, drill 1/8" pilot holes.
-
For walls or floors composed of drywall,
sheet-rock or other soft materials, drill 3/16"
holes to a minimum depth of 1-3/4", then tap
plastic anchors into each of the holes using
a hammer.
-
For walls or floors composed of concrete or
concrete block, drill 3/16" holes to a mini-
mum depth of 1-3/4", then tap concrete
anchors into each of the holes using a
hammer.
-
For walls or floors having ceramic tile cover-
ing, drill 3/16" holes through the tile only, then
drill into the material behind the tile as indi-
cated immediately above.
• If the range is moved to a new location, the Anti-
Tip Device must be removed and reinstalled.
MOUNTING ANTI-TIP BRACKET
The alternative floor mounted bracket shall be installed
as follows:
a) Place bracket on floor in position shown in Figure
7B.
b) Secure to floor or wall stud.
c) Later, when the unit is installed, the adjustable leg
will slide under the bracket.
FIG. 7B
2-1/2"
➤
➤
from edge of range
2-1/2"➤
➤
(typical -
either side)
FIG. 7A - Mounting Anti-tip Bracket
IMPORTANT INSTALLATION INFORMATION: