Thermador PH30HS Ventilation Hood User Manual


 
English 5
Off
Pressing the button once turns ventilator off and resets the
control.
Fan Speed
Pressing the button once, from an “off” state, turns the
ventilator on low. Each successive press of the button
increases the fan speed until high speed is reached, then
the fan cycles back to the low speed.
The LEDs above this button indicate the current fan speed.
When the fan is on, the corresponding LED is illuminated.
1 — Low
2 — Medium
3 — High
Auto (only on 27” models)
When in Auto mode, the hood automatically turns the
blower on, depending on the amount of heat the control
senses. It automatically adjusts every 5 minutes. If the
control does not sense a high level of heat, it will turn the
blower off.
Delay (shut off)
If the blower is off when the Delay button is pressed, the
blower will turn on to the HIGH speed setting for 10
minutes. At the end of the cycle the blower will turn off.
If the blower is on when the Delay button is pressed, the
blower runs for 10 minutes at the current speed then turns
off.
During the 10 minute timed period, the LED above the
Delay button is illuminated.
To interrupt a timed period, press Fan Speed or OFF
button.
Clean Filter Reminder
After 40 hours of operation, the LED above the filter button
will illuminate indicating that the filters need to be cleaned.
When this indicator illuminates, clean the filters as
instructed on page 6. After cleaning, press this button for 3
seconds to reset the 40-hour period and turn the LED off.
Light On/Dim/Off
This button controls the halogen lighting. The first press
turns the lights on. A second press dims the lights. A third
press turns the lights off.
Heat Lamp (only on 27” models)
The buttons marked “L” and “R” independently control the
left and right infrared heating lamps, turning the lights on or
off.
Heat Sensor Protection
Over Temperature Condition
The high temperature sensor protects the hood from high
temperatures which may damage components. The control
is set to activate at 161°F (72°C) and reset at 140°F (60°C).
When activated, the blower will turn on low and the
corresponding LED will blink, indicating an over-
temperature condition.
While the high temperature sensor is activated, the blower
speed can be manually changed or turned off. If the blower
is turned off, the corresponding LED will blink. Light
controls will remain operational. When the control sensor
reaches 140°F (60°C), a reset will occur. During reset, the
control will revert back to the operational state prior to the
high temperature condition.
High Temperature Fault Condition
If in the uncommon occurrence the Heat Sensor Protection
becomes damaged, the three fan speed indicator LEDs will
start blinking. All of the controls will continue to be
operational except for the indicator LEDs. To reach a
service representative, see the contact information at the
back page of the manual.