Introduction
Before using your appliance, be sure to read this manual.
Pay special attention to the Important Safety Instructions
located at the beginning of the manual.
This manual provides the proper care and use instructions
for two styles of THERMADOR PROFESSIONAL
®
PH
Series wall hoods:
• PHxxGS — 27” (686 mm) in depth, with widths of 36”
(914 mm), 42” (1067 mm), 48” (1219 mm), and 54”
(1372 mm). This model series features brushed
stainless-steel canopy with halogen lamps and heat
lamps.
• PHxxHS — 24” (610 mm) in depth, with widths of 30”
(762 mm), 36” (914 mm), and 48” (1219 mm). This
model series features brushed stainless-steel canopy
with halogen lamps.
All hoods require the choice of a Remote, Inline, or Integral
Blower. Use only THERMADOR
®
blowers with
THERMADOR ventilation hoods. All blower models are
sold separately. See Table 1, Blower & Circuit Breaker
Ratings for recommended blowers. Contact Customer
Service for additional options.
All Hood models are rated for 120 VAC, using a 15 amp or
20 amp circuit breaker; see the Installation Manual for more
details.
When connected to a GFCI-protected supply, the Pro
Hoods are suitable for use in damp locations that are
protected from outside weather conditions and not subject
to saturation with water and other liquids, but can be
subject to moderate degrees of moisture. Refer to local
codes, NEC/CEC, and or the Authority Having Jurisdiction
(AHJ) for additional information.
Blower SKU CFM Voltage (AC)
Blower Current
(AMPS)
Circuit Breaker
(AMPS)
Remote Blower 600 CFM VTR630D 600 120 4.2 15
Remote Blower 1000 CFM VTR1030D 1000 120 5.7 15
Remote Blower 1300 CFM VTR1330E 1300 120 8.5 20* / 15**
Inline Blower 600 CFM VTI610D 600 120 4.2 15
Inline Blower 1000 CFM VTI1010D 1000 120 5.7 15
Integral Blower 600 CFM VTN630C 600 120 2.7 15
Integral Blower 1000 CFM VTN1030C 1000 120 5.4 15
* 20 Amp circuit breaker required when using the VTR1330E Remote Blower with a 27” Pro Wall Hood.
** 15 Amp circuit breaker required when using the VTR1330E Remote Blower with a 24” Pro Wall Hood.
Table 1: Blower & Circuit Breaker Ratings