Thermador PH48CS Ventilation Hood User Manual


 
PAGE 7
Heat Lamp Replacement
Turn heat lamp counterclockwise to remove.
Replace lamp with either a PAR-38 175W heat
lamp or a PAR-40 250W heat lamp.
The PAR-38 175W heat lamp provides a tighter
seal within the enclosure and produces the same
amount of effective heat with lower energy con-
sumption. These lamps may not be readily available
at local retail outlets. The PAR-40 250W heat lamp
is more widely available. It can be used instead.
PAR-38 175W heat lamps can be purchased
through the following retailers:
• OpTech Inc: 800-848-6624
• bulbs.com: 888-455-2800 or www.bulbs.com
CAUTION
Do not touch the bulbs immediately after use.
The bulbs will remain hot for several minutes. Do
not place highly flammable material on warming
shelves.
MAINTENANCE
Lights
NOTE: Turn off the lights and fan. Allow the lights
to cool before handling. If new lights do not oper-
ate, be sure lights are inserted correctly before
calling service.
Halogen Light Replacement
Using a flat edge from a screwdriver or equivalent
tool, pry loose the lens cover as shown in Figure
5.
Remove the damaged light and replace with a
new 12 Volt, 20 Watt (maximum) halogen light
made for a G-4 base. Follow package direc-
tions and do not touch new light with bare
hands.
Reinstall the light and cover.
Figure 4
Figure 5