III. c - INSTALLING LEGS OR CASTERS (cont'd):
the factory inside a cardboard box which is secured
inside the cabinet. Casters in lieu of legs are supplied
as an optional accessory for all compact undercounter
models. The casters are stem type, and do not re-
quire the use of any bolts. When ordered, casters
are shipped in a separate box.
WARNING: THE CABINET MUST BE BLOCKED AND
STABLE BEFORE INSTALLING LEGS OR CASTERS.
Raise up and block the cabinet a minimum of 7" from the
floor and thread the legs into the threaded holes on
the bottom of the cabinet (see figure 1).
Thread optional casters into the threaded holes on
the bottom of the cabinet in the same way (see figure 2).
Casters with brake should be installed at the front.
Level the cabinet using a level or pan of water in the
bottom of the cabinet. On units with legs, turn the
adjustable feet in or out to level the cabinet side-to-side
and front-to-back. Units with casters should be placed
on level floors.
II. RECEIPT INSPECTION
All Traulsen products are factory tested for perfor-
mance and are free from defects when shipped. The
utmost care has been taken in crating this product to
protect against damage in transit. All interior fittings
have been carefully secured and the legs or casters
are boxed and strapped inside to prevent damage.
You should carefully inspect your Traulsen unit for
damage during delivery. If damage is detected, you
should save all the crating materials and make note
on the carrier's Bill Of Lading describing this. A freight
claim should be filed immediately. If damage is sub-
sequently noted during or immediately after installa-
tion, contact the respective carrier and file a freight
claim. Under no condition may a damaged unit be re-
turned to Traulsen & Co. without first obtaining writ-
ten permission (return authorization).
III. a - LOCATION:
Select a proper location for your Traulsen unit, away
from extreme heat or cold. Condenser performance
is dependent on adequate ventilation for cooling
purposes. Adequate clearance MUST be provided
for the ventilator locations underneath. There are
no clearance requirements for sides, rear, or top.
NOTE: Do not install the cabinet without legs, cast-
ers or front ventilated utility base.
III. b - PACKAGING:
All Traulsen units are shipped from the factory bolted
to a sturdy wooden pallet and packaged in a durable
cardboard container. The carton is attached to the
wooden skid with the use of large staples. These
should first be removed to avoid scratching the unit
when lifting off the crate.
To remove the wooden pallet, first if at all possible, we
suggest that the cabinet remain bolted to the pallet
during all transportation to the point of final installa-
tion. The bolts can then be removed with a 5/8 socket
wrench by tipping or otherwise raising the unit to al-
low access to them. Avoid laying the unit on its front,
side or back for removal of the pallet.
NOTE: Traulsen does not recommend laying the unit
down on its front, side or back. However, if you must
please be certain to allow the unit to remain in an up-
right position afterwards for 24 hours before plugging
it in so that the compressor oils and refrigerant may
settle.
III. c - INSTALLING LEGS OR CASTERS:
6 high legs are supplied standard for all Traulsen
compact undercounter units. These are shipped from
III. INSTALLATION
III. INSTALLATION (continued)
Fig. 2
-2-
Fig. 1