III. h - CLEARANCE:
It is important for the proper operation and longevity
of your Traulsen unit that it have adequate provisions
underneath for air supply to the compressor. There
are no clearance requirements for the sides, rear or
top.
NOTE: Do not install the cabinet without legs, casters
or a front ventilated utility base.
III. i - OPTIONAL UTILITY BASE:
An optional utility base is available, in lieu of legs
or casters, for models UHT27, ULT27, UPT276 &
UPT279 only. To install this, follow the directions
below see (figure 4):
1. Place utility base in final installed location.
NOTE: The front of the utility base must be
oriented towards the front. Fastener locations
are provided for anchoring utility base to floor,
if desired; fasteners are not provided.
2. Place unit on top of utility base so holes
underneath are aligned. The plug cord must be
routed from the bottom right rear corner of the
unit through a slotted hole in the utility base.
Assemble the strain relief (provided) around the
electric cord and route it through the slotted
hole in the utility base.
III. INSTALLATION (continued)
-3-
Fig. 3
Fig. 4
Fig. 5
III. c - INSTALLING LEGS OR CASTERS (cont'd):
Please note that Traulsen units are not designed to
be moved while on legs. If the unit requires moving,
a pallet jack or forklift should be used to prevent
damage.
III. d - SHELF CLIPS:
Shelves and shelf clips are shipped with the unit.
For each shelf, insert four (4) shelf clips into the
pilaster slots at the same height (Fig. 3). The shelf
clips have a small projection on top which holds the
shelf in position and prevents it from slipping forwards.
After installing shelf clips on pilasters, place shelves
on clips.
III. e -
CORD & PLUG:
All UHT, ULT & UPT models are supplied with a cord &
plug attached. It is shipped coiled at the bottom of
the cabinet, secured by a nylon strip. For your safety
and protection, all units supplied with a cord and plug
include a special three-prong grounding plug on the
service cord. Select only a dedicated electrical outlet
with grounding plug for power source. NOTE: Do not
under any circumstances, cut or remove the round
grounding prong from the plug, or use an extension
cord.
III. f - POWER SUPPLY:
The supply voltage should be checked prior to con-
nection to be certain that proper voltage for the cabi-
net wiring is available (refer to the serial tag to deter-
mine correct unit voltage). Make connections in ac-
cordance with local electrical codes. Use qualified
electricians.
Use of a separate, dedicated circuit is required. Size
wiring to handle indicated load and provide necessary
overcurrent protector in circuit (see amperage require-
ments on the unit’s serial tag).
III. g - WIRING DIAGRAM:
Refer to the wiring diagram for any service work per-
formed on the unit. Should you require one, please
contact Traulsen Service at (800) 825-8220, and pro-
vide the model and serial number of the unit involved.