True Manufacturing Company TCGG-48-S Refrigerator User Manual


 
............ www.truemfg.com ............
True Food Service Equipment, Inc.
8 8
INSTALLATION / OPERATION INSTRUCTIONS
Step 5
A. The compressor is ready to operate. Plug in the
unit.
B. Check the temperature control setting in the
upper left of the cabinet backside. The setting
should be at #5 to maintain an approximate
38˚F (3.3˚C). Set defrost time clock to the
correct time of day.
NOTE
Excessive tampering with the control is not recommended as
this can lead to service difficulties. Should it ever become
necessary to order a replacement temperature control, be sure it
is ordered from a dealer or recommended parts stocking service
company.
C. Verify that the cabinet lights are working. Deli
cases are shipped with light switches in the “on”
position. The toggle switch is located upper left
corner at the rear.
NOTE
If the deli case is disconnected or shut off, wait five minutes
before starting again.
RECOMMENDATION
Before loading product we recommend you run your True
unit empty for two to three days. This allows you to be sure
electrical wiring and installation are correct and no shipping
damage has occurred. Remember, our factory warranty does not
cover product loss!
REPLACEMENT PARTS
TRUE maintains a record of the cabinet serial number for your
unit. If at any time during the life of your display case, a part
is needed, you may obtain this part by furnishing the model
number and serial number to the company from whom you
purchased the cabinet. Call Toll-Free: (800)-424-TRUE (Direct
to Parts Department). (800)-325-6152 (U.S.A. & Canada only)
or call: (636)-240-2400.
STARTUP
Serial Number
Step 4
A. Before your new unit is connected to a power
supply, check the incoming voltage with a
voltmeter. If anything less than 100% of the
rated voltage for operation is noted, correct
immediately.
B. All units are equipped with a 9 ft. (3m) service
cord, and must be powered at proper operating
voltage at all times. Refer to cabinet data plate
for this voltage.
True requires that a sole use circuit be dedicated
for the unit. Failure to do so voids warranty.
WARNING
Compressor warranties are void if compressor burns out due to
low voltage.
WARNING
Power supply cord ground should not be removed!
NOTE
To reference wiring diagram - Remove front louvered grill,
wiring diagram is positioned on the inside cabinet wall.
ELECTRICAL INSTRUCTIONS
Curved Glass Deli Cases
Deli cases are equipped with a service receptacle
(found on the upper left cabinet backside),
no electrical load greater that 4.0 amps
should be connected to it. If the electrical
load is greater that 4.0 amps, it should be wired
separately or a larger lead cord should be wired
in place of the provided lead cord. Use a cord
with a 20 amp male plug (NEMA-5-20P).