True Manufacturing Company TFP-32-12M-D-2 Oven User Manual


 
............ www.truemfg.com ............
99
True Food Service Equipment, Inc.
INSTALLATION / OPERATION INSTRUCTIONS
A. Thecompressorisreadytooperate.Pluginthe
cooler.
B. TemperaturecontrolsetatNo.4positiongives
refrigeratorsanapproximatetemperatureof35°F.
Allowunittofunctionseveralhours,completely
coolingcabinetbeforechangingthecontrolsetting.
C. Excessivetamperingwiththecontrolcouldleadto
servicedifficulties.Shoulditeverbecomenecessary
toreplacetemperaturecontrol,besureitisordered
fromyourTRUEdealerorrecommendedservice
agent.
D.GoodairflowinyourTRUEunitiscritical.Be
carefultoloadproductsothatitneitherpresses
againstthebackwall,norcomeswithinfourinches
oftheevaporatorhousing.Refrigeratedairoffthe
coilmustcirculatedownthebackwall.
NOTE
If the cooler is disconnected or shut off, wait five minutes before
starting again.
RECOMMENDATION
Before loading product we recommend you run your TRUE unit
empty for two to three days. This allows you to be sure electrical
wiring and installation are correct and no shipping damage
has occurred. Remember, our factory warranty does not cover
product loss!
REPLACEMENT PARTS
TRUE maintains a record of the cabinet serial number for your
cooler. If at any time during the life of your cooler, a part is
needed, you may obtain this part by furnishing the model number
and serial number to the company from whom you purchased
the cooler. Call Toll-Free: (800)-424-TRUE (Direct to Parts
Department). (800)-325-6152 (U.S.A. & Canada only) or call:
(636)-240-2400.
Thetemperaturecontrolislocatedarethebackofthe
unit.(Seeimage1).
TEMPERATURE CONTROL LOCATION
Image 1
SEQUENCE OF OPERATION
Temperature Control Sequence of Operation
Whenthecabinetispluggedtheunitwillstartupinadefrostcycle.Theevaporatorfanishard-wiredandwill
continuetorunduringthistime.Thecoolerwillstayindefrostforaminimumof4minutesoruntilthecoil
temperaturereachesatleast41˚F.Themaximumtimethecoolerwillbeindefrostis40minutes.Attheendof
thedefrostcycle,therewillbea2minutedelaytoallowanywatertodripoffoftheevaporatorcoil.Afterthis
time,thecompressorswillcomeonandthecoolershouldstarttocooldown.Thecompressorswillrununtilthe
temperaturecontrolissatisfied.Every4hoursofcompressorruntime,thecoolerwillgointodefrostandremain
indefrostuntilthecoiltemperaturereaches41˚F.
NOTE:
Whentheunitisfirstpluggedinitwilltakeatleast6minutes
beforethecompressorstarts.
STARTUP