True Manufacturing Company THF-41FL Freezer User Manual


 
............ www.truemfg.com ............
True Food Service Equipment, Inc.
7
7
INSTALLATION / OPERATION INSTRUCTIONS
Step 4
A. Before your new unit is connected to a power supply,
check the incoming voltage with a voltmeter. If anything
less than 100% of the rated voltage for operation is
noted, correct immediately.
B. All units are equipped with a 6 ft. (2.74m) service
cord, and must be powered at proper operating voltage at
all times. Refer to cabinet data plate for this voltage.
True requires that a sole use circuit be dedicated for the
unit. Failure to do so voids warranty.
WARNING
Compressor warranties are void if compressor
burns out due to low voltage.
WARNING
Power supply cord ground should not be
removed!
NOTE
To reference wiring diagram - Remove front
louvered grill, wiring diagram is positioned on the
inside cabinet wall.
MANUAL DEFROST
The unit will need to be manually defrosted. Unplug
unit until all frost is gone. The manual defrost
frequency will depend on the units usage, environment,
and the amount of frost.
If ice builds up on interior walls-
A. Remove product, unplug and roll unit so defrost plug
is above floor drain (or large flat pan).
B. Remove plug and allow ice to melt and drain. Do
not scrape interior of cabinet to loosen ice, as this will
damage the cabinet. Allow cabinet to defrost with power
off.
C. When ice has melted wipe up and water left in the
freezer floor.
D. Be sure to replace defrost plug before moving freezer
back in position.
E. Allow freezer to refrigerate and cycle before placing
wire baskets and product back into freezer.
ELECTRICAL INSTRUCTIONS
STARTUP
Step 5
A. The compressor is ready to operate. Plug in the
Freezer.
B. Check the temperature control setting on the upper
right of the compressor grill. The setting should be at
#5.
NOTE
If the freezer is disconnected or shut off, wait five
minutes before starting again.
NOTE
Excessive tampering with the control is not
recommended as this can lead to service difficulties.
Should it ever become necessary to order a
replacement temperature control, be sure it is ordered
from a dealer or recommended parts stocking service
company.
RECOMMENDATION
Before loading product we recommend you run your
True unit empty for two to three days. This allows you
to be sure electrical wiring and installation are correct
and no shipping damage has occurred. Remember,
our factory warranty does not cover product loss!
REPLACEMENT PARTS
TRUE maintains a record of the cabinet serial number
for your freezer. If at any time during the life of your
freezer, a part is needed, you may obtain this part by
furnishing the model number and serial number to
the company from whom you purchased the freezer.
Call Toll-Free: (800)-424-TRUE (Direct to Parts
Department). (800)-325-6152 (U.S.A. & Canada only)
or call: (636)-240-2400.
NOTE:
When loading product do not exceed product
load line labeled on the interior wall
of unit. (see photo)
Photo