4. Clean the condenser coil
(Figure 15, 1)
using a using a
soft brush with a “combing” action or vacuum cleaner.
Do not touch the condenser coil.
Figure 16
5. Make sure grille cap
(Figure 16, 1)
is behind grille in
slots
(Figure 16, 2)
provided in grille before attaching
grille to unit, and secure, but do not overtighten both
grille screws
(Figure 16, 3)
.
6. Reconnect power to the unit.
Models 1175R and 1175BEV
1. Disconnect power to unit.
Figure 17
2. Loosen the two screws
(Figure 17, 1)
completely.
NOTE: Screws are held in the grille by o-ring retainers,
and will not come free of the grille.
3. Remove grille from unit.
4. Clean the condenser coil
(Figure 17, 2)
using a using a
soft brush with a “combing” action or vacuum cleaner.
Do not touch the condenser coil.
Figure 18
5. Place the hook-hinge
(Figure 18, 1)
located on the
rear bottom side of the grille onto the front lip
(Figure
18, 2)
of the unit base. Swing the grille up into
position, and align the screw holes on the grille to the
grille screw hole on the cabinet.
6. Secure, but do not overtighten both grille screws
(Figure 18, 3)
.
7. Reconnect power to unit.
Leveling
It is important that units equipped with adjustable feet
are level, for proper door and ice maker (if equipped)
operation.
NOTE: Models 29R DO NOT have leveling feet. These
models MUST be placed on a level surface to operate
properly.
To level units with adjustable feet:
Figure 19
1. Use a level to check the levelness of the unit from
front to back and from side to side. Level should be
placed along top edge and side edge as shown
(Figure 19).