46
User’s Manual
DO NOT touch the condenser fins. The condenser fins are
SHARP and can be easily damaged.
4. Clean the condenser coil using a soft brush with a “combing” action
or vacuum cleaner. Do not touch the condenser coil. The condenser
coil may be located on either the right or left side of the base.
Figure 45
5. Place the two hook-hinges (located on the rear bottom side of the
grille) on the front lip of the unit base. Swing the grille up into
position, aligning the grille and cabinet screw hole (Figure 45).
6. Position the grille to align the screw holes with the cabinet.
7. Insert the grille screw and tighten. Do not overtighten.
The solenoid valve inlet screen must be cleaned at least once each
year as follows:
1. Shut off the water at the water supply valve.
2. Remove the entire hose connector from the solenoid valve.
UL107
!
WARNING
30035 User Manual Body.qxd 1/5/05 8:08 AM Page 46