Problem Possible Cause Remedy
The unit is not Airflow to front grille Airflow must not be
cold enough (cont.) blocked obstructed to front grille.
See INSTALLATION or
CLEANING AND
MAINTENANCE.
Temperature not set Turn control knob
cold enough CLOCKWISE to set
temperature colder.
Allow 24 hours for
temperature to stabilize.
The unit is not cold The door was left open Turn off the unit to manually
enough (Frost free causing the evaporator defrost the evaporator.
units only) behind the back wall to See DEFROSTING.
fill with frost preventing
proper air flow and
cooling.
The unit frosts Unit is manual Models SP18, 95, 98,
up defrost model and Combo 29A and
75A are manual defrost.
Refer to DEFROSTING.
Door gasket not Adjust door. See
sealing properly ALIGNING THE DOOR.
High ambient Defrost unit manually.
temperatures or See DEFROSTING.
humidity
Water is leaking Water supply Tighten fitting. See
out the back connection leaking CONNECTING THE
of the unit WATER SUPPLY.
Ice cubes Door gasket not Adjust door. See
sticking together sealing properly ALIGNING THE DOOR.
Infrequent use of cubes Break apart cubes.
Noise during Copper water supply Carefully bend tubing
operation tubing contacting away from cabinet and
internal components components.
Certain sounds are Soft sounds from the fan
normal. and water/dropping
sounds from the ice maker
will be heard.
Fan blade touching Remove obstruction.
obstruction (wiring,
foam insulation, etc.)