U-Line CLRCO2075 Ice Maker User Manual


 
www.U-LineService.com 14 02/2005
CLRCO2075 — Clear Ice Maker/Refrigerator
IMPORTANT
Before installing your U-Line CLRCO2075 with Factory-
Installed U-Line P60 Pump, it is extremely important to
check and test all hose connections at the drain pump.
There is a possibility that hose connections may have
loosened during shipment.
WARNING
To prevent accidental electrocution, make certain
that the floor surfaces surrounding the unit are
dry whenever power is removed from, or applied
to, the unit.
To check and test hose connections:
1. Make certain the unit is not plugged into an electrical
outlet.
2. Carefully push the power cord grommet through the
hole in the back panel (see
Figure 35
).
3. Remove 12 screws and back panel.
WARNING
Back panel serves as a guard. DO NOT put your
hands inside the ice maker cabinet or attempt to
touch any components except the discharge tube
during testing. Failure to follow this warning
could result in serious personal injury or death.
4. Check that the clamps and hose connections are tight at
the following areas (see
Figure 36
):
Discharge tube (A)
Drain tube (B)
Vent tube (C)
Air Gap
(Optional Hook-Up)
Cold
Water
Hot
Water
Waste
Shut-Off
Valve
Figure 33
Disposal Assembly
Waste
Cold
Water
Shut-Off
Valve
Hot
Water
Air Gap
(Optional Hook-Up)
Figure 34
Spigot Assembly
Power
Cord
Grommet
Drain
Fitting
Back
Panel
Water
Connection
Screws
Figure 35
Back View Side View
BB
A
C
C
Figure 36