U-Line CLRCO2075 Ice Maker User Manual


 
www.U-LineService.com 20 02/2005
CLRCO2075 — Clear Ice Maker/Refrigerator
Start-Up Troubleshooting
Problem
Q
:
Unit does not appear to turn on when switch is set to ON.
Solution
A:
Remember that the compressor will not operate until the
water has been filling for about 3 minutes. Make sure unit
is plugged in and outlet has power (circuit breaker has
not tripped). If the unit is equipped with a drain pump,
check that the drain line is not obstructed (LED #3 will
blink) — unit will shut down due to the safety design of
the pump if water cannot drain.
Note: LED #3 only applies to units equipped with a drain
pump. If LED #3 flashes on a unit without a drain pump, a
jumper on the board is missing and needs to be replaced
before the Ice Maker will work.
Problem
Q
:
Water does not appear to be flowing into unit.
Solution
A:
Check that the water is connected and turned on, the line
is not obstructed and the overflow tube is inserted
securely into water trough.
Problem
Q
:
The unit has been operating for 24 hours and water is still
not flowing evenly over evaporator.
Solution
A:
Level unit for even water flow. Uneven water flow will
reduce ice rate and cause water to spill in ice bin.
IMPORTANT
See the User Manual’s Troubleshooting Guide for more
solutions.