U-Line CLRCO2075 Ice Maker User Manual


 
02/2005 3 www.U-LineService.com
CLRCO2075 — Clear Ice Maker/Refrigerator
General Precautions
Use this appliance for its intended purpose only and
follow these general precautions along with those listed
throughout this guide:
WARNING
SHOCK HAZARD — Electrical Grounding Required.
Keep the unit unplugged throughout installation
except during testing.
Never remove the round grounding prong from
the plug and never use a two-prong grounding
adapter.
Never use an extension cord to connect power to
the unit.
Always keep your working area dry.
CAUTION
Use care when moving and handling the unit. Use
gloves to prevent personal injury from sharp edges.
Do not lift the unit by the door or door handle.
Do not install the unit behind closed doors or in any
way that would obstruct airflow to the front grille,
which may cause the unit to malfunction.
You have received a carton containing your CLRCO2075
Clear Ice Maker/Refrigerator with a package inside
containing a User Manual, a Product Registration Card
and water connection parts. Complete and mail the
Product Registration Card or register online at
www.U-LineService.com. Once your unit is installed,
keep the User Manual and this Installation Guide in a
safe place for future reference.
Your unit is Black, White or Stainless Steel. Black and
White units have a reversible door with a slightly
contoured handle across the top. They come with a flush
mounted door panel that, when removed, will accept a
custom 1/4-inch thick door panel or a 3/4-inch thick full
overlay door panel. Stainless Steel units are covered with
a protective coating and have been ordered left- or right-
hand hinged. The Stainless doors are not reversible and
do not accept custom panels. CLRCO2075 Clear Ice Maker/
Refrigerators may be ordered with a factory-installed
drain pump. Please carefully follow the directions that
apply to your unit and your intended design.
Tools/Materials Required
7/64" Allen wrench
Screwdrivers — slotted and Phillips head
1/4-inch OD copper tubing and shut-off valve for water
supply line
5/8-inch ID drain line
P60 Drain Pump (if required and not already factory
installed, see Page 13)
1/4-inch thick door panel material and cutting tools
(Black or White units)
Full Overlay Door Panel Kit (part number U-OL2075B —
Black or part number U-OL2075W — White), 3/4-inch
door panel overlay, cutting tools, drill and bits (Black or
White units)
Inspection
Unwrap and inspect the unit on a flat, level surface
capable of supporting its entire weight.
Removing Protective Coating
(Stainless Steel Units Only)
When inspecting/installing a Stainless Steel unit, the
protective coating covering the unit must be removed
first. Start at a corner of the unit/door and pull back the
protective coating to remove it from the unit/door.
2 Inspect and Plan