U-Line CO2075DWR Refrigerator User Manual


 
47
Design
Features
Performance
2. Some cooling
• Clean condenser.
Check condenser fan.
Possible system leak.
3. No cooling
Check compressor/fan operation
Check refrigeration system pressure
Check wiring and power at circuit board
4. Noise
This is a frost free unit with two fans, compressor, and two solenoid valves. Some noise is normal
such as a hum from the fans/compressor. Also, during an ice harvest it is normal to hear water fill-
ing the mold and cubes dropping in the bucket.
5. Condensation on mullion
The mullion has a heater behind it. The heater is always energized and should keep the mullion
free of frost and sweat. In extremely humid conditions some sweat may appear on the mullion or
lower drawer handle/gasket.
6. Excessive frost
Frost may be visible through the evaporator cover slots.
Any buildup on the bottom of the liner could be caused by failure to clean up spilled ice cubes.
If evaporator is not defrosting, the board can be manually entered into a defrost cycle using the
diagnostic feature.
If evaporator or drain pan does not clear during a defrost, check the bypass valve coil for continuity.
Drawers not closing properly.
7. Display not operational
Check four conductor wires from main board to display board. The display board should have red
light and flashing green light on the rear of the board. If these lights are not lit, the wire is not con-
necting to the main board.
8. Dot flashing on display
If a thermistor goes out of range it will illuminate a dot on the display board. This dot will remain lit
even if the thermistor goes back into range. It can be cleared by switching the unit off and back on.
9. Drawers will not close properly
The drawer slides contain a self-closing feature which engages when the drawer is about 1 inch
from being closed. At the point the closers engage, there may be some resistance. If this resistance
is hard to overcome, try closing the drawers with more force a couple times. If, during shipment,
the unit has been mishandled, the drawer slide closers may become disengaged. Reset by closing
the drawers with more force than normal.
10. Evaporator fan not operational
Ensure fan is not restricted.
CO2075DWR