U-Line CO2075DWR Refrigerator User Manual


 
51
Design
Features
Performance
4. Water fill cycle
This cycle initiates when the blades move to approximately the 10 o’clock position.
At this point the ice has moved out of the mold and is dropping into the bucket.
The ice maker switch is depressed for about seven seconds while the mold fills with water. The
water fill is approximately 120 ml.
At the end of the fill cycle, the blades stop at the 12 o’clock position and wait for another harvest
cycle to begin.
5. Storage mode
The bin arm is in the up position, either held by ice in the bin or manually raised.
The unit will be cycling the compressor on and off in this mode.
The ice maker relay will energize when the ice maker reaches 15°F, but with the bin arm in the raised
position, it will not start an ice making cycle.
DWR056
CO2075DWR