20
®
CAST IRON STOVE AND BURNER SYSTEM
106707
For more information, visit www.desatech.com
SBVRBN AND SBVRBP
1. After lighting, let pilot flame burn for
about one minute. Turn control knob
on the control valve to ON position.
Turn flame adjustment knob any-
where between HI and LO. Slide the
selector switch to the REMOTE posi-
tion.
Note:
The burners may light if
hand-held remote ON button was on
when selector switch was last turned
off. You can now turn the burners on
and off with either optional hand-held
remote control unit.
IMPORTANT:
Do not leave the se-
lector switch in the REMOTE posi-
tion when the pilot is not lit. This will
drain the battery.
IMPORTANT:
Be sure to press the
ON/OFF buttons on the hand-held
remote control unit for up to 3 sec-
onds to assure proper operation.
OPTIONAL REMOTE
OPERATION
Note:
All remote control accessories must
be purchased separately (See Accessories
on page 27). Follow instructions included
with the remote control.
Thermostat Control Operation
(Optional GHRCTA Only) The thermo-
stat control setting on the remote control
unit can be set to any comfort level be-
tween WARMER and COOLER. The
burners will turn on and off automatically
to maintain the comfort level you select.
The ideal comfort setting will vary by
household depending upon the amount of
space to be heated, the output of the cen-
tral heating system, etc.
NOTICE: You must light the pilot
before using the hand-held re-
mote control unit. See
Lighting
Instructions,
page 19 .
GHRC Series Operation:
2a. Press the ON/OFF button to turn the
burners on and off. When turning
burners off, the pilot will remain lit.
GHRCTA Series Operation:
2b. Press the AUTO/ON/OFF button on
the hand-held remote control (see
Figure 50). The lights to the left of
the button will show AUTO, ON, or
OFF.
• In the ON mode, the burners will
ignite. The heater is in manual
mode when ON is lit.
Figure 49 - Setting the Selector Switch,
control Knob, and Flame Adjustment
Knob for Remote Operation
• In the AUTO mode, the thermostat
in the hand-held remote unit con-
trols the room temperature. To in-
crease the room temperature, press
the top arrow of the TEMP button.
To lower the room temperature,
press the bottom arrow of the
TEMP button. At higher settings
the heater will run longer.
IMPORTANT:
This remote control
has been specially engineered to
take an air temperature sample ev-
ery 5.5 minutes in the auto mode.
It will not respond immediately to
the temperature setting being
turned up or down.
IMPORTANT:
The hand-held re-
mote control unit must be near the
heater. Do not keep the hand-held
remote control unit too close to the
heater. The thermostat on the
hand-held remote control unit will
heat up too quickly and turn the
heater off.
3. To turn the burner off, press the
AUTO/ON/OFF button until OFF
lights. The pilot will remain lit.
IMPORTANT:
To turn the pilot off,
manually turn the control knob on the
heater to the OFF position.
ON
OFF
REMOTE
L
O
H
I
OFF
ON
P
I
L
O
T
Selector Switch in
Remote Position
(Optional Remote
Control)
Flame Adjustment Knob
Control Knob
in On Position
OPERATING STOVE
WITH B-VENT
BURNER SYSTEM
Continued
Figure 50 - Hand-Held Thermostat Remote Control Unit Selections
(GHRCTA Only)
Increases Room
Temperature in
AUTO Mode
Decreases Room
Temperature in
AUTO Mode
Turns Burner On
or Off and Allows
You to Choose
the Auto Setting
Shows Temperature Setting
The Log Heater will
Automatically Cycle between
Pilot and the Heat Setting
that has been Selected