Venmar HRV 2600* Ventilation Hood User Manual


 
6.4 WALL CONTROLS CONFIGURATION
See the configuration table below for the list of configuration parameters.
Press the Menu button for 3 seconds to enter or exit the configuration menu.
NOTE: The wall control automatically saves any changes and exits the configuration menu if no button is pressed within the
next 60 seconds.
Press the Menu button briefly to advance to the next parameter (menu number).
Press the or button to change the parameter setting.
CONFIGURATION TABLE
6. CONTROLS (CONT’D)
MENU
PARAMETER OPTIONS
DEFAULT
DESCRIPTION
NUMBER SETTING
1TEMPERATURE FORMAT °C / °F °C SELECTS BETWEEN °C AND °F DISPLAY.
2A
UTO MODE OPERATION RE / OF RE
S
ELECTS BETWEEN AIR RECIRCULATION (RE) AND OFF (OF)
(SEE SECTION 6.3).
3
AUTO MODE LOW -30°C TO 0°C -25°C PREVENTS AIR EXCHANGE IN AUTO MODE IF THE OUTDOOR
TEMPERATURE LIMIT (-22°F TO 32°F) (-13°F) TEMPERATURE IS TOO LOW (SEE SECTION 6.3).
4
A
UTO MODE HIGH 0°C TO 30°C 27°C PREVENTS AIR EXCHANGE IN AUTO MODE IF THE OUTDOOR
TEMPERATURE LIMIT (32°F TO 86°F) (81°F) TEMPERATURE IS TOO HIGH (SEE SECTION 6.3).
AU: THE SCREEN ILLUMINATES FOR 12 SECONDS WHEN ANY
5BACKLIGHT MODE AU / ON AU KEY IS PRESSED
ON: THE SCREEN IS PERMANENTLY ILLUMINATED.
- 19 -