21
12c
Air Gap
12d
Air Gap
(Discharge with air gap)
(Discharge with food waste disposer and air gap)
13
14
Connect water line.
Plug LED light into dishwasher (select models only)
and install kick plate.
Note: DO NOT block the dry air exhausts (rectangular
slots on the access panel) with kick plate or base board.
Blocking the opening could reduce the dry performance
and cause unwanted condensation.
Final Installation (cont.)
20
9a
x2
3
1
2
x4
9b
x2
For installation with trim (451 model), secure
dishwasher by attaching provided mounting plugs and
wood screws through trim panels into cabinets. Attach
screws through top brackets into cabinets.
For installation without trim (301 model), secure
dishwasher by attaching screws through top brackets
into cabinets.
Note: DO NOT
use mounting plugs.
Minimum
20”
(50.8 cm)
from floor
10
1.0”
(2.5 cm)
Cut here for
3/4” (1.9 cm)
Cut here for
5/8” (1.6 cm)
11
Install High Loop Clip, which is provided, a minimum of
20” (50.8 cm) from the floor. Refer to the Drain section
of
"General Information"
for proper installation
requirements.
Identify discharge connection size; cut line to correct
size and connect. Clamp if necessary.
12a
12b
(Discharge with food waste disposer)
Note: Be sure to remove the knockout or plug from the
fitting of the disposer before connecting drain line.
(Standard discharge)
Final Installation