13
3
4
Close the door until it stops.
Push in/lift door up/and then out. Repeat for all doors.
5
6
Remove racks.
Unscrew pallet screws from side of oven.
Neutral
Green
White
Black
Red
7a
Neutral
Green
White
Black
Red
7b
Wiring option 1*
(connect the white and green to the incoming neutral)
Wiring option 2*
(connect the white to the incoming neutral,
attach green to grounded junction box)
Installation (cont.)
*Note: Check local code to see which wiring option should be used when grounding the unit.
12
1
1
2
2
Remove wooden brace on front of pallet.
Open door completely. Rotate door
hinge to unlocked position.
Installation
General Information
Site Preparation
Note: It is recommended that a thorough
site inspection be conducted PRIOR to
unpacking and moving this appliance.
• Confirm available access to adequate
power—see electrical requirements.
°
Single oven units require a 30 amp circuit
°
Double oven units require a 50 amp circuit
• Note: A minimum of 2” spacing above
and below the oven to any adjacent items
is required for ventilation purposes.
• It is recommended that 3/4” or thicker
material be utilized to create a support
platform for this appliance.
• BE SURE that support for this appliance is
perpendicular to the front facing of the
wall or cabinet before you perform the
installation.
• Use of a hydraulic lift is recommended for
the installation of double oven units. Be
careful not to bend lower trim/vent.
• All openings in the wall behind the
appliance or in the floor under the
appliance should be sealed.
• Keep appliance area clear and free from
combustible materials, gasoline and other
flammable vapors.
WARNING
DO NOT use the handle or oven door to lift
the oven. Remove door before installation
to ensure that it is not used to lift the unit.
DO NOT lift or carry the door by the handle.
WARNING
FIRE OR ELECTRICAL
SHOCK HAZARD
DO NOT use an extension cord
with this appliance. Such use
may result in fire, electrical shock
or other personal injury.