Viking F21287A EN Ventilation Hood User Manual


 
98
24”
(61.0 cm)
A
18”
(45.7 cm)
12”
(30.5 cm)
6”
(15.2 cm)
A (Hood width)
30”W. 29-7/8“ (76.2 cm)
36”W. 35-7/8” (91.1 cm)
42”W. 41-7/8” (106.4 cm)
48“W. 47-7/8” (121.6 cm)
60”W. 59-7/8” (152.1 cm)
(VWH 18”H. 24” Deep Wall Hoods 30”, 36”, 42”, 48”, & 60”)
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-
grill. Max duct run is 50 ft (15.2 m).
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft (22.9 m)
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
30”min.
(76.2 cm)
to
36”max.
(91.4 cm)
66”min.
(167.6 cm)
to
72”max.
(182.9 cm)
36”
(91.4 cm)
(VWH 18”H. Wall Hoods)
NOTE: Optional duct cover sold separately.
VWH 18”H. Wall Hoods
Description 30” 36” 42” 48” 60”
Duct cover width
29-7/8”
(75.9 cm)
35-7/8”
(91.1 cm)
41-7/8”
(106.4 cm)
47-7/8”
(121.6 cm)
59-7/8”
(152.1 cm)
Duct cover depth
12” (30.5 cm)
Duct cover height
12” (30.5 cm)
Number of filters
2 2 2 3 4
Heat lamps
1 1 1 2 3
Interior ventilator kits
VINV300/
600/1200
VINV300/
600/1200
VINV600/
1200
VINV1200* VINV1200*
Exterior ventilator kits
DEV900/
1200*
DEV900/
1200*
DEV900/
1200*
DEV1200*/
1500**
DEV1200*/
1500**
In-line ventilator kits
DIL1200 DIL1200 DIL1200 DIL1200 DIL1200
Interior duct size
7”/10”
(17.8/25.4 cm)
7”/10”
(17.8/25.4 cm)
7”/10”
(17.8/25.4 cm)
10”
(25.4 cm)
10”
(25.4 cm)
Exterior duct size
10” (24.5 cm)
Interior—Maximum amps
4.2/5.2/8.2 4.2/5.2/8.2 5.2/8.2 10.8 10.8
Exterior—Maximum amps
8.0/5.3 8.0/5.3 8.0/5.3 7.8/8.5 7.8/8.5
In-Line—Maximum amps
5.3/7.2 5.3/7.2 5.3/7.2 9.6 10.0
Dimensions & Specifications
Clearance Dimensions