2120
1
2
Measure the four corners in cutout area to verify if
flooring is level.
For uneven or sloped floors, level unit with metal shims
only, as the adjustment required may exceed
the thread available in the leg.
3
4
3
/8
”3/8”
(0
.
9
5
c
m
)
(0.95 cm)
3
/8
”
(0
.
9
5
c
m
)
Move unit into opening.
Leveling/Adjustments/Alignment
Electrical Connection (4-wire)
(cont.)
5
Check that unit is level side to
side and front to back. Side trim of the high corner
must be 3/8” (0.95 cm) above countertop.
If leveling is required, move unit out of opening.
6
1
2
1
Lift unit and prop on wood blocks.
4
Feed supply cord up through hole in bottom
of range back.
5
6
Attach ground lead (green)
with ground screw that was removed.
Attach line #1 (red) and line #2 (black)
leads to outside terminal. Attach neutral wire (white) to
center terminal on terminal block.
1
1
7
8
Push supply cord toward terminal
block to relieve strain, reattach supply cord strain
relief bracket over supply cord.
Reattach access door.