Vulcan-Hart 1ER50AF Fryer User Manual


 
6
INSTALLATION
Before installing the fryer, verify that the electrical requirements agree with the
specifications on the fryer data plate, which is located on the inside of the door panel.
Record your fryer model, device, and serial numbers for future reference in the space
provided below. This information can be found on the fryer data plate.
Fryer Model No: ___________________________
Device: ___________________________________
Serial No: ________________________________
CODES AND STANDARDS
The fryer must be installed in accordance with:
In the United States:
State and local codes, or in the absence of local codes, with:
National Electrical Code, ANSI/NFPA-70 (latest edition). Copies may be obtained
from The National Fire Protection Association, Batterymarch Park, Quincy,
MA. 02169-7471.
In Canada:
Local codes
CSA C22.1 Canadian Electric Code L4W 5N6.
ASSEMBLY
The fryer must be restrained to prevent tipping and the splashing of hot liquid. The means
of restraint may be the manner of installation, such as connection to a battery of
appliances, installing the fryer in an alcove, or by separate means such as adequate ties.
Fryers with Casters: (Optional)
Separate instructions for installing casters are included with the casters:
The restraining device should be attached to the cutout on the back panel. See
illustration for location.